Skip to content
Flash Sale Live Now: Setra Lite @10% Off with Code "LITE10OFF"
Flash Sale Live Now: Setra Lite @10% Off with Code "LITE10OFF"

Setra FLEX Room Pressure Monitor

$3,230.18
SKU FLEXR05WBRM7SN

Setra FLEX™ is a complete monitoring and control solution in a pre-configured and easy-to-use package. Offering all of the essential parameters that require monitoring, the FLEX will meet all of your critical environment needs.

Download Data Sheet Operating Instructions 

Note for Buyers: If you're interested in the 'monitor & controller' or 'configurable' models of the Setra Flex, or if you have any specific requirements for pressure pickups or any other customizations, contact us below.

Contact Us 

Setra FLEX™ provides a flexible room environmental control and monitoring solution in a simple-to-use package. An attractive flush mount face plate is complemented by an intuitive graphical display to meet any architectural requirement.

More Than a Room Pressure Monitor 

The unit supports 3 rooms, monitoring up to 6 parameters for each room. These optional additional parameters can include humidity, temperature, occupancy, particle count, door status, air velocity, and many more environmental factors. An optional differential pressure sensor can be either factory-installed in the unit or ordered separately and installed above the ceiling. Integration with building automation systems is made easy through either BACnet/IP or BACnet MS/TP network protocols.

Modular Design

A modular hardware design enables FLEX to fit in various wall thickness found around the globe. For applications which require the monitor to fit in wall depths less than 50mm, FLEX can be ordered with an external pressure sensor. When mounting in a three gang electrical box, FLEX can be ordered with an integrated on-board sensor. Sufficient on-board I/O provides connectivity for most common equipment and sensor applications. A high accuracy of 0.25% differential pressure transducer is used in all pressure sensing options. A projected capacitive touch screen provides swipe functionality and allowed for use with medical gloves. The face plate is attached to the unit body, enabling both tamper resistant operation and easy opening for pressure calibration.

Setra FLEX-RM and FLEX-RC

FLEX software is designed to suit any application, with the ability to support up to 3 rooms. FLEX-RM (Room Monitor) provides monitoring only, for those applications where no control from the touch screen is needed. FLEX-RC (Room Control) offers monitoring, plus PI loop or network control of VAV boxes, venturi valves, or hydronic reheat valves. Software is pre-installed, with configuration and network integration done using simple setup screens. There is no programming required. When completed, configuration settings on one unit can be cloned to other devices using a standard USB thumb drive, thereby shortening commissioning time. Units can also be configured remotely over a BACnet network.

FLEX's monitor is both a controller and a monitor, with audible and visual alarming on all room parameters. FLEX's monitor enables users to save energy by choosing from two PI control loops and two monitoring sets for any of four room modes, such as occupied and unoccupied.

Optional adapter boxes are available for installations where cutting into the wall is not possible.